KitLog pro

Powered By Kitlog Pro v2.0

N144GP Lancair Super ES
' style=
Date:  6-27-2010
Number of Hours:  0.10
Manual Reference:  
Brief Description:  flip VR so terminals are facing down; per B&C and

slide VR#2 down about 1/2" to give clearance for wires (shifted holes)
latest LOBO newsletter had article about an incident that involved a B&C VR and water getting in. Suggested that they be installed with terminals facing down, if not on the inside of firewall. New LS-1A VR from B&C this week had a sticker from B&C indicating such (see yellow sticker on VR #2)
' style=

fliiped VR #1 so terminals are facing down

fliiped VR #1 so terminals are facing down

' style=

closer view

closer view

' style=

wires run; 18 AWG; box and terminal #7 grounded

wires run; 18 AWG; box and terminal #7 grounded

' style=