tighten all flap control bolts; tighten set nuts; torque seal all
reposition flap position sensor rod to torque tube to account for moving torque tube forward by 1.5".
set up VP settings for flaps... VERY COOL! Set up settings for 10, 25 and 40 degree flaps and set up for one touch....touch once down and flaps go to 10, touch again they go to 25, etc. One touch up takes the flaps the whole way up...can stop by pushing down. Speed setting is variable too, but I am leaving at default for now...seems fine