Boy, this wiring job aint so simple. I sure hope these heaters keep me warm! I had to add 2 more adel clamps to the forward nose bulkhead. I'm creating a new path for both heater wires that will be clean and neat. I stepped down from Deans plugs and went with XT60 instead for 2 reasons. 1, they create a MUCH better weather tight seal, and 2, they are rated for a constant 60 amps which is 4 times the amount I need. The Fuses will be located just behind the nose bulkhead out of site, but easy to access. I ran out of 14awg wire so I used the 14awg wire that came with the units. I'd prefer Tefzel instead but I'm too impatient to hold up the whole job for another 4 days. Knowing they are fire retardent like Tefzel, I have no worries. I should have this heater installation completed by tomorrow! How exciting :)