Date:  5-26-2011
Number of Hours:  2.00
Manual Reference:  
Brief Description:  Ran Backup Power Wires to the AHRSs

Ran Backup Power Wires to the AHRSs after I realized that the EFISs had Secondary Power Supply from the TCW IBBS but the AHRSs only had a Primary Power source. To remedy this, I spliced a wire into the Secondary Power Supply wires at the EFISs and then ran this AHRS Secondary Power wire into a splice with the Primary Power source wire at the AHRSs' connectors. the common wire from this splice ws plugged into the connectors of their respective AHRS. Now, when the voltage to the EFISs and the AHRSs dips, the Secondary Power source from the TCW ISSB to the EFIS will power the Secondary Power for the AHRS.
' style=

EFIS Secondary Power Splice

EFIS Secondary Power Splice

' style=

Primary & Secondary to AHRS

Primary & Secondary to AHRS

' style=

Splice to AHRS Connector

Splice to AHRS Connector

' style=