Brief Description: Re-routed #6 Cable to the Aft Power Terminal
Re-routed #6 Cable to the Aft Power Terminal to keep tyhe cable from passing through any structures. Initially, I routed the cable aft through a snap bushing in a bulkhead and them through a snap bushing in the forward aluminum bar that supports the Vertical Power Control Unit. Using an aluminum angle riveted to the F-808 bulkhead, the cable now passes around the bulkhead and through adel clamps that secure its path to the Power Terminal. This alteration decreases the chance of having a hot cable from the batteries severed by the fuselage structure in an accident.