Brief Description: Vertical Power VP-X Pro Test Bench
Received my Master and Starter solenoids today. Installed the solenoids on the bench. Installed the diodes and fabricated a power bar between the Master and Starter solenoids. Installed the power lead to the Master and to the VP-X Pro. Grounded the Starter solenoid. I temporarily wire in a switch as the master and powered the system up. I checked voltage throughout the circuit, showing 13.93 volts.
I will be fabricating a mount for all the switches tomorrow... and start pinning out for the VP-X.