Brief Description: Temporarily connected and tested trim rocker & LED
Made temporary connection of all leads from the servo, rocker and LED to test the operation of the system. Things worked perfectly. The alignment of the trim tab when LEDs are centered is precise. Closed up the access to the servo. Empennage structure and trim tab system test complete.