Brief Description: Drilled Pitot Heat Controller to Access Panel
The Dynon pitot heat controller was drilled to the rib in the left access panel. The flanges of the pitot heat controller were then drilled for nutplates. The access panel and rib flanges were dimpled. The pitot heat controller flanges were countersunk. The nutplates were then riveted to the pitot heat controller.