I completed installing the EGT/CHT wires in their new locations and made the electrical connections to the Dynon EMS wires on both sides. Another job out of the way. I will now replace all the zip ties with lacing cord and also cover the staggered connections to prevent junk from collecting on them.....
Staggered each connection to keep from creating a bulge in the whole thing.
Be careful slicing the outer brown cover on Dynon EMS wires. Don't cut the underlying wires.
I covered the connections and tied it off with lacing chord everywhere.