Date:  11-5-2021
Number of Hours:  5.00
Manual Reference:  DWG OP 22
Brief Description:  Installed New Electrical Boots & Engine Ground

I installed a solid copper connector and new boots between the Master Battery Contactor and the Starter Solenoid Contactor because I felt my previous connections placed unnecessary strain on the Contactors and the new boots will protect the electrical connections from inadvertent shorting, since they are exposed near the battery housing. I also installed the Engine ground wire from the firewall to the engine block; mounting dual Adelle Clamps to hold the wire to the engine mount framework.
' style=

Copper Connection & Boots

Copper Connection & Boots

' style=

Engine Ground to Firewall

Engine Ground to Firewall

' style=

Engine Ground to Block

Engine Ground to Block

' style=