Brief Description: Completde buss manager installation and engine mon
Finished installation of the EFII buss manager and addded three amphenol bulkhead feedthrough connectors to the firewall for the engine monitor wiring. Completed the wiring between the GEA24 interface the the bulkhead connectors. I installed the shunt for monitoring alternator current on the top of the buss manager housing.
Completed buss manager with shunt for alternator current on top
Amphenol bulhead connectors on aft side of firewall