RV-8 N998W
' style=
Date:  3-20-2010
Number of Hours:  4.00
Manual Reference:  
Brief Description:  First engine start

Leak, vent, pressure and flow checked. Repaired leak at fuel press tranducer. Fuel pressure with Aux fuel pump 25 psi. Flow rate 45 gal/hr. Checked mixture operation at engine pump. Adjusted throttle cushion at rear throttle. Trimmed empennage fairing.