Date:  8-7-2016
Number of Hours:  5.00
Manual Reference:  6W
Brief Description:  Cables Connected to elevator horn

Revoved horizontal stab and elevator to get access to the elevator horns. Attached cables and reinstalled tail section. My plan is to cut these cables where they cross the bottom access door and put the turnbuckles at this location. I had enough problems getting the control stick out of the center box without all the strff that will be eventually installed in it. Since the plans show the turnbuckle installed in the box, I saw no easy way to get to the bottom turnbuckle without a great deal of frustration when it came to safety wiring the turnbuckle and when adjusting/setting cable tension.
' style=

Cable to upper forn

Cable to upper forn

' style=

Cable to lower horn

Cable to lower horn

' style=