Brief Description: Elevator push-pull tube installation
Cleaned up excess powdercoating in pushrod guide bushing mount hole. And bonded guide bushing in place with structural epoxy. Fabricated elevator push-pull tube from aluminum tubing stock, bushing adapters, and threaded rods. Assembled parts with structural epoxy and stainless steel pop rivets. Added check nuts and rod ends to tube assembly. Installed tube in fuselage and connected to idler bellcrank.