Date:  4-3-2011
Number of Hours:  6.00
Manual Reference:  ?
Brief Description:  Completed Secondary Regulator wiring

Dressed up and laced the wires for the secondary alternator regulator. Provided a sufficien service loop so that the regulator could be unmounted and brought down into the cabin for adjustment of the regulator voltage. Case has a separate ground wire running to the single point ground so that it is not isolated when unmounted.