Date:  3-20-2022
Number of Hours:  0.00
Manual Reference:  
Brief Description:  Avionics Calibration pt. 10

Downloaded updated all system software except transponder, which was unavailable. Tested #2 EGT probe with heat gun; indicator fails above 100°F. Problems incurred while calibrating autopilot servos was traced to an incorrect pinout location on the pitch servo connecter; repaired.