Clip all the tie-wraps and organized the harnesses for the VP-100. new tie-wraps on each J- connector, routed to the pivot rail forward of subpanel. This will allow the VP-100 platform mount to swing down while completely connected, and full access to the connectors.
Attached Dynon 36" SV-net cable from EMS to area of SV-1000, but may decide to mount a SV-Hub on the top side of the VP-100 swing tray, and reconnect there.
Routed SV-net cables from the roll & pitch servos to equipment bay. Routed 'soft-start' power cables which will power the landing light (left wing) and taxi light (right wing). Attached Molex pins on the "Red Cube" fuel transducer.