Date:    8-20-2008
Number of Hours:    0.80
Brief Description:    Flap controls
Mount HC-115 flap handlle detent plate on aft side of left HF-90TP with 1/8" rivets.

Assemble flap push rod (HC-12) L&R ends with HS-26, -2A, -23, -25 end fittings secured each with 2 1/8" HM-17 straight rivets peened over as shown in Dwg. 10A.