| Date: |
4-4-2016 |
|
| Number of Hours: |
4.00 |
|
| Brief Description: |
CONDENSER PLENUM |
|
|
1 Make four 90 deg mounting flanges out of 3 bid layup. Start with rectangular patches 2 wide x 3 long. Form the patches into angles with the short leg of the angle 3/4 long. 2 Centre the condenser over the plenum opening and mark the location of the condenser attachment flanges. 3 Using 2 bid layup, attach the angle tothe plenum to coincide with the condenser attachment flanges. The short side of the angle is used for conderser attachment. 4 Using hysol or floax , bond the condenser plenum into the fusalge. ref to fir 16.2.A.2 |
||