Installed an electric flap motor instead of the manual flap handle. Used the existing flap brackets installed under the seats and fabricated a bracket to secure the telaflex cables. Mounted the linear actuator in the supplied flap handle brackets. Connected to a battery and tested system. Worked perfectly.