Date:  7-14-2015
Number of Hours:  4.00
Manual Reference:  Kit 2&3
Brief Description:  Flap and trim sensor

Flap sw is connected to10A fuse with a AWG 16 wire and one similar to ground. Two wires, already installed to flapmotor, now connected to sw.
3 AWG 22 wires from flap position connected to Daqu +5V and ground and one to B3. Some voltage measurements to understand which.
Trim sw will be positioned to stick grip, not delivered yet, 4 wires installed to stick. +12V, ground, and power to flapmotor. 3 wires to Daqu +5V, ground and B4. AWG 22 used to extend supplied wires.
Than calibration of position 0 and 100% was done according to manual. Good instructions make it easy to understand.