- Rolled leading edges for both elevators - Hung elevators and trimmed H/S so elevators would swing freely. Trimmed H/S aft spar to allow for correct down travel. - Checked up/down travel - seems to be in spec at ~30 up, 30 down. - Checked elevators for binding - left elevator has a little binding on the inboard leading edge. Right elevator travels freely.