KitLog pro

Powered By Kitlog Pro v2.0

Bob's RV-8 Build Site
' style=
Date:  6-1-2022
Number of Hours:  2.60
Manual Reference:  
Brief Description:  Regulators

Having completing the main and standby alternator switch connections I focused my attention on the other end at the wires for the connection at the regulator in the electrical bay. I routed the wires along the back wall of the electrical bay with the other wires.

I removed the customized adel wall clamp that I made to hold the wires to the back wall and cut off some of the lacing to get the two new wires tied in along with all the other wires. After getting them laced and set to where they need to lay so I reinstalled the flat adel clamp which works great to hold the wires solidly to the back wall.

After getting the wires to that point I put the labels and ring terminals on the field wires and connected all the terminals to the standby and main alternators.
' style=

Routing and re-lacing wire bundle along back wall

Routing and re-lacing wire bundle along back wall

' style=

Main & Stby Alt Field wires labeled and ready

Main & Stby Alt Field wires labeled and ready

' style=

All wires attached to regulators

All wires attached to regulators

' style=










Copyright © 2001-2024 Matronics. All Rights Reserved.