Date:  9-26-2015
Number of Hours:  5.00
Manual Reference:  
Brief Description:  Cowling fasteners Part 1

With the nosebowl drilled out to final holes, I decided to finalize the cowling fasteners. These are quality quarter-turn fasteners from Mil-Spec Products Inc. In image 1, you see the 0.032" insert I bent up to reinforce the lower panel. The fastener receptacles need to be affixed to this insert with countersunk rivets, since the insert will sit against the inside of the lower panel. Image 2 shows two receptacles in their positions. Image 3 shows the insert rivetted to the inside of the panel.