KitLog pro

Powered By Kitlog Pro v2.0

Ron Lendon's Aircraft Mfg.
< Previous Log Entry          Next Log Entry >
' style=
Date:  10-8-2012
Number of Hours:  1.00
Manual Reference:  
Brief Description:  Airflow through Cowl

Now the air inlets are 4.9" in diameter with a 7 degree venturi flange on the inside of the inlet. The area for the inlet time two is 37.715"

The exit is basically made up of 4.25 x 17.7 rectangle and two 2 x 3 triangles for a area of 78.25" combined for the exit.

37.715 / 78.25 = 0.4819808306709265 or invert

78.25 / 37.715 = 2.07477131114941

for twice as large exit area.
' style=
< Previous Log Entry          Next Log Entry >










Copyright © 2001-2024 Matronics. All Rights Reserved.