Peters Web Site
|
Date: 12-21-2020
|
Number of Hours: 1.00
|
Manual Reference:
|
Brief Description: Flap Indicator.
|
|
I configured the flap indicator using the VP-X " Configurator App " on my laptop. The Sling 4 has four flap positions, up 0*, flap 11*, flap 20* and flap 32*. I entered some temporary flap position settings in the VP-X App and rebooted the VP-X and G3X. The flap indicator now displays the two mid flap positions. One push on the flap switch, flaps run to flap 11* position, second push flaps run to flap 20* position, etc. The thing that we need to be very aware of is, in the case of a go-around, selecting flap up, the flap runs at a reduced rate, but continues all the way to the flap up position. If we touch the flap switch a second time on a go-around the flaps stop running at that present position. Flap position " F " is on the left side, Elevator trim position " E " is on the right side.
|
|
Before configuration.
|
|
After configuration.
|
|
Laptop connected to the VP-X.
|
|
|
|
|
|
|
|
|