Determined the location for Dynon's Pitot tube/AOA heating controller box in wing according to installation notes and references found in Dynon's Heated AOA/Probe Installation Guide page 2-1. Final location determined to be inside LH wing inside third inspection bay outboard (in second lightening hole aft of inspection bay's outboard rib).
Measured and match-drilled four holes in 10th rib, second lightening hole aft using heating controller holes as guide. Used new holes as guide for installation of four K1000-06 nutplates with flush rivets. Deburred all holes and primed scratches in area. Riveted nutplates to rib. Controller is attached using four AN515-8R8 (round head) screws, each with one 9/64 ID aluminum washers. Installation notes and references found in Dynon's Heated AOA/Probe Installation Guide page 2-1.
Determining location for Heat controller box installation
Match drilling according to dimensions template in manual
Final setup of installed nutplates and adel clamps to secure cables