Date:  1-25-2008
Number of Hours:  5.00
Manual Reference:  
Brief Description:  Primary wiring forward of firewall

Using Bob Nuckholls' Interim Z-24 OV protection architecture, I wired from the Alternator B lead to one side of the S701-1 Alternator OV Disconnect contactor. It took a while to fabricate the #6 AWG wire because I made the flag connectors from 3/4 copper pipe. Next, fabricated a brass strap with a 90 degree twist from the ANL series Limiter to the other post of the S701-1.
' style=

B-lead wiring

B-lead wiring

' style=

S701-1 wiring, B-lead connects on the bottom left

S701-1 wiring, B-lead connects on the bottom left

' style=

Strain relief for wiring

Strain relief for wiring