purchased 2 HC-05A sequencing valves from a lancaire builder . These will be installed next . They will be placed with the gear stop . These are a manual operated valve - when the gear comes back to rest on the stop - the actual gear leg will depress the valve button and thus allow hydualic pressure to be fed to the secondary gear door ram - closing the door.