Date:  10-22-2018
Number of Hours:  3.00
Manual Reference:  
Brief Description:  Pitot/Static System Checked & Passed

There was initially an interface issue with tools. Improved connection indicater no leaks.

1. ADCCERT: Altimeter has been tested and found to comply with FAR 43. App E.
2. TXPSCERT: Transponder and transponder automatic altitude reporting system have been tested as required by FAR 91.4111/413 and found to comply with FAR 43. App E and F.
3. SSCERT: Static system was tested as required by FAR 91.411 and found to comply with FAR 43. App E.
' style=

Altimeter Readings

Altimeter Readings

' style=

Transponder Cert

Transponder Cert