Date:  4-27-2012
Number of Hours:  0.00
Manual Reference:  
Brief Description:  Temperature Labels

The temperature on the P-Mags are slightly critical and they also need a cooling blast tube so I thought it might be a good idea to monitor the temperatures with spot labels.

Whilst at it I put one on the Odyssey battery and EFIS Data Acquisition Unit to see if it will need a jacket to insulate it from the FWF heat.

Here are details of the labels in a pdf

I bought them in the UK from OMEGA part number 4A-170 these have spots for 77 / 82 / 88 / 93 deg C which are good for the P-Mags (limit 88 deg C) and the Odyssey Battery (80 deg C)

As of Dec 2015 One spot (77C) on the P-Mags none on my battery or EFIS data acquisition unit located on the firewall.
' style=

P-Mag

P-Mag

' style=

Battery

Battery

' style=

Omega A4-170 Label

Omega A4-170 Label

' style=