Reamed out four battery lugs to 5/16" for connection to master relay and starter solenoids. Secured aft run of positive battery cable with Adel clamp. Cut short cable for battery-master relay connection and crimped lugs in place. Cut forward end of positive cable to length and crimped lug. Sent battery tray specs to Oliver Reik; he 3D printed a prototype.