Date:  2-11-2020
Number of Hours:  2.00
Manual Reference:  
Brief Description:  Engine Preservation pt. 6; Duct Work

Inspected all four cylinders with borescope; no changes. Fogged cylinders with preservative. Clamped heat muff duct tube to right aft baffle. Applied anti-chafe tape layers and standoff zip ties to several potential chafing areas.