KitLog pro

Powered By Kitlog Pro v2.0

Greg's RV-12 Classic N719VA
' style=
Date:  8-28-2020
Number of Hours:  3.00
Manual Reference:  SL-00010
Brief Description:  wire up the CO monitor wires to EMS connector

SL-00010 connected the wires for the CO monitor to the EMS 47 pin connector. Connected grounds to pin 3 and 5, connected CO monitor signal to pin 10 (GP6), connected the SPO2 signal wire to pin 21 (GP10). Will need to finish the setup in the Dynon. Soldered the pins to the wires, did not have the proper crimp tool, worked well. Had to spiple into the wht/red wire from the EMS connector pin 18 for 5V. Soldered and heatshrink two layers.
' style=

CO monitor wires to EMS conn

CO monitor wires to EMS conn

' style=










Copyright © 2001-2024 Matronics. All Rights Reserved.