KitLog pro

Powered By Kitlog Pro v2.0

Greg's RV-12 Classic N719VA
' style=
Date:  8-29-2021
Number of Hours:  2.00
Manual Reference:  48
Brief Description:  install EGT sensors

Manual 48-07 steps 1 & 2 - install two EGT sensors, one on Cyl. #3 and one on Cyl. #4. Had to slightly enlarge the holes in the exhaust tubes with #30 drill bit for sensor to fit. Holes were barely too small for the sensors to fit inside.
' style=

#3 cylinder sensor

#3 cylinder sensor

' style=

#4 cylinder sensor

#4 cylinder sensor

' style=