Date:  11-14-2020
Number of Hours:  12.00
Manual Reference:  Step 3
Brief Description:  Panel Layout

The Dynon HDX1000 EFIS was powered up for the first time. Starting them up was straight forward and eventless. All of the network devices have been detected and the Dynon network has no errors At first there were some software revision mismatches, so the entire system was upgraded to the newest level, which is 15.4.7 released on June 6, 2019.

The serial communication was setup for the GPS-2020 and the ADSB-472, both were successful and are working admirably.

The serial communication for the VPX has not been set up yet. I requested the license code; however, it will take between 1-3 days to recieve it.

The transponder serial communication was set up, but has not successfully communicated. This will require more troubleshooting.

Both back up batteries were installed and charged successfully. After they were charged up, they were tested according to Dynon's procedure, which is to turn off all ship power and time to make sure that battery can support operation for at least 45 minutes. Both batteries passed this test.