Powered EFIS and iBox through the electronic circuit breaker (ECB). Several dipswitch profiles were tried along with grounding ECB circuits 1 and 2. Grounding(bridging) the ground did not activate the breaker(s) everytime the power was cycled. Build a wiring harness with CAN bus connections and ground with a DB9 and to enable programming the ECB. Was able to program the EBC from the EFIS, setting profile 31, breaker name, trip time, trip current, and startup state.