Dr. Pete's Xenos Build
' style=
Date:  11-3-2018
Number of Hours:  1.00
Manual Reference:  AeroVee
Brief Description:  Starboard Cylinder Heat Temp Thermocouples

Blocked starboard intake ports to prevent chips from entering. Drilled #36 holes 9/16" deep for Aeroconversion thermocouple mount. Installed thermocouples with supplied self-tapping screws. Marked cylinder number and RDAC input point on thermocouple wire with printed heat shrink tubing.
' style=

.

.

' style=




' style=

heat shrink markings

heat shrink markings

' style=