KitLog pro

Powered By Kitlog Pro v2.0

ALBERT'S WEB SITE
' style=
Date:  7-28-2009
Number of Hours:  1.00
Manual Reference:  WW
Brief Description:  Primer solenoid and canopy hold open.

Rechecked fuel system, found primer solenoid wired so the with power on primer solenoid was open and when toggled it was closed. Changed the wiring on the switch and then checked good.
Last time I rechecked it I checked with out the power on, using the #2 pump right from the battery and was fooled into thinking it was O.K.
Put in 60 lb cartridges on canopy to hold open more positively.
' style=





' style=




' style=










Copyright © 2001-2024 Matronics. All Rights Reserved.