Bobs Ten
' style=
Date:  7-6-2018
Number of Hours:  6.00
Manual Reference:  
Brief Description:  Install Main DC Contactor Deck

This is the first entry after a lightning strike fried the shop computer.

A new computer was installed and reloaded.

I spent time on the 6th and 7th designing and fabricating contactor mounts for the main DC busses.

I am using a hybrid system based on the Z-14 diagram. I was not comfortable running two #8 wires from aft to front wired direct to the batteries as there would be no way to isolate the batteries. I opted for the addition of two bus feed contactors for that possibility. It means two extra switches, however, in the unlikely event of a short, I can disconnect the battery from the faulted bus feed.

Jumpers were fabricated from #2 welding cable to connect the contactors.

Standard techniques were used in all fabrication.