Date:  4-29-2012
Number of Hours:  0.50
Manual Reference:  
Brief Description:  02 - Shunt signal leads

Shunt signal leads

First I added clear heatshrink around the shunt itself for general insulation, then cut holes where the terminals contact. Then I fabricated the signal leads, which pass via 1A fuses to the EFIS for current display, both into and out of the battery.