Date:  4-28-2012
Number of Hours:  1.00
Manual Reference:  
Brief Description:  04 - Avionics power

Avionics power

I replaced the 14 AWG avionics power wires with a 12 AWG (for added safety margin) and bridged the upstream side of the shunt to the start circuit distriubtion block. The avionics wiring run is short, but there could be as much as 30A continuous running through the avionics power wires at times.