Date:  10-28-2021
Number of Hours:  4.00
Manual Reference:  
Brief Description:  VPX & IBBS Wiring

Today I was able to tidy the VPX J2 plug wiring & splice some bridging wires to parallel the 4 output wires from the IBBS. Each IBBS output can support a maximum of 3.5 amps continuous however there is a limit of 5 amps total for all the outputs so by paralleling them, they can all share the load. I mowed the lawn too.
' style=

Soldered bridging wires

Soldered bridging wires

' style=

Neat enough I think

Neat enough I think

' style=

VPX wiring tidied & IBBS output wires in place

VPX wiring tidied & IBBS output wires in place

' style=