KitLog pro

Powered By Kitlog Pro v2.0

DAVID'S WEB SITE
' style=
Date:  4-4-2016
Number of Hours:  4.00
Manual Reference:  16.2.C
Brief Description:  CONDENSER PLENUM

1 Make four 90 deg mounting flanges out of 3 bid layup. Start with rectangular patches 2 wide x 3 long. Form the patches into angles with the short leg of the angle 3/4 long.

2 Centre the condenser over the plenum opening and mark the location of the condenser attachment flanges.

3 Using 2 bid layup, attach the angle tothe plenum to coincide with the condenser attachment flanges. The short side of the angle is used for conderser attachment.

4 Using hysol or floax , bond the condenser plenum into the fusalge. ref to fir 16.2.A.2
' style=