Date:  12-2-2018
Number of Hours:  4.00
Manual Reference:  
Brief Description:  CO Guardian wiring

Solder spliced extra wire lenght onto the two SV display harness that I designated for the CO Guardian RS232 in and out signals.

Cut a 22 ga wire to lenght for the CO guardian ground.

Cut and terminated with a D-sub receptical the power, ground and RS232 wires for the CO Guardian making sure to leave enough wire for a service loop to allow the CO guaradion to be removed from the panel for service. Slid a lenght of expandable sleeving along with two short lenghts of shrink tubing on the the four wires.

Installed the D-sub connector, reinstalled the CO detector and connected the connector.

Cut and labled wires for VP-X Pro Ground and SV-Display power wires. Installed the VP-X Pro ground wires in the VP-X connectors and routed the wires.
' style=

CO Guardian wire harness

CO Guardian wire harness

' style=

CO Guardian wire harness connected

CO Guardian wire harness connected

' style=