Date:  2-19-2009
Number of Hours:  1.00
Manual Reference:  
Brief Description:  test flight

Two start attempts caused the 200A fuse to blow.

Oxygen system showed “Error”, did not repeat.

Left and Right Aileron rolls performed normally.
Left and Right Barrell rolls performed normally.
Left and Right wingover performed normally.

Speed brakes op checked at 250 KIAS
Autopilot power up in flight operates normal, engage and disengages normally, responds normally to inputs.

Stalls:
Clean =76 KIAS, Slight buffet/ Stall warning at 77 KIAS
10° Flaps =73 KIAS, Slight buffet/ Stall warning at 75 KIAS

Changed Oil at conclusion of flight.

Consideration for inlet area reduction upon temperature verification of engine parameters during warmer climate conditions in the summer months.