Wired pitot heat indicator to EMS contact 2. Ran power, ground and indicator wiring to L & R fuel quantity and fuel flow sensor. Ran new wire for oil temperature indicator, fuel pressure indicator and power wire for fuel pressure sensor. Installed Molex connectors on fuel and oil pressure sensors. Ran electronic ignition wires to coils. Tightened bulkhead MAP fitting. Installed Molex connector on fuel flow transducer and set Dynon K value to 68000.