Date:  1-5-2018
Number of Hours:  6.00
Manual Reference:  
Brief Description:  Prepared and installed 180 deg thermostat

Modified a Misere p/n 101 inline thermostat hoiusing by adding a new 1 in. tubing inlet.
Installed using 1 in inlet hose and an1.25 in by 1.0 in 45 deg. outlet hose.
The thermostat is chev 350 181deg. Stant product. Refilled with Evans coolant and purged air from system